Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors

Product Details
Customization: Available
Warranty: 12months
Type: Water-Cooled
Manufacturer/Factory
Gold Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
Import & Export Mode
Have Own Export License
  • Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors
  • Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors
  • Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors
  • Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors
Find Similar Products

Basic Info.

Model NO.
RHT-040WL
Cooling Method
Water-cooled
Unit Structure
Integral
Selected Voltage
380V/50HZ
Compressor Number
1
Noise Level
Low
Application Fields
Chemical
Application Machine
CNC Machine Tools
Certification
ISO, CE
Condition
New
Capacity Controlling
0-100%
Frequency
50/60Hz
Size
2175X935X1430mm
Weight
1020kg
Cooling Capacity
132kw
Controller
Punp or Siemens
Transport Package
Plywood Case
Specification
Standard quality. SGS, CE
Trademark
Ruihai
Origin
Shenzhen
HS Code
8418699090
Production Capacity
5000 Sets/ Month

Product Description

Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors

Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors


Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors

Features

1. Providing -60ºC~5ºC frozen refrigerant, suitable for different customers and refrigeration capacity requirements.

2. Intelligent control, adjust compressor output automatically according to the load and keep the unit in highest efficiency
at any time.

3. Adopting the latest medium and low temperature semi-hermetic single screw type compressor or the most
advanced gear ratio is 5:6 imported semi-hermetic twin screw type. Compressor is equipped with unloading       b    capacity control device, and, multistage or infinitude energy regulation is available.

4. Evaporator is using internal thread high efficient copper tube, and, combined with the unique structure design has the advantage of super heat exchange, compact structure, reliable oil return, easy to maintain, etc.

5. Shell and tube type condenser is using high efficient copper tubes, with the advantages of high heat transfer efficiency, 
reliable heat transfer, high performance, washable and convenient maintenance.

6. The microcomputer controlling system, with powerful security protection, communication, fault diagnosis, automatically adaptation and other function.


 
Specifications
Model No. RHT
-040WL
RHT
-050WL
RHT
-060WL
RHT
-070WL
Power Supply 3PH-380V-50HZ
Cryogenic Temperature -8ºC Kcal/h 54180 69660 77400 92020
KW 63 81 90 107
-10ºC Kcal/h 49020 63640 70520 83420
KW 57 74 82 97
Air Conditioner's
Refrigeration Capacity
Kcal/h 113520 141900 165980 191780
KW 132 165 193 223
Power Consumption KW 27.9/27.5/31 34.9/34.4/38 39.4/38.9/43 46.2/45.5/51
Operating Current A 50.0/49.5/54 64.9/61.3/66 69.3/68.6/75 80.1/79.2/87
Starting Current A 218D/411DD 269D/508DD 290D/485DD 350D/585DD
Capacity Control % 100-75-50-25-0
Compressor Type Semi-hermetic Screw Type
Qty 1
Starting Fractional Winding
Oil Heater (W) 200
Freezing Oil Type B320SH
Vol (L) 9 9 15 15
Refrigerant Type  Eco-friendly R134a or R407c
Vol (Kg) 21 26 30 35
Control Thermostatic Expansion Valve
Evaporator Type Shell and Tube Type High Efficiency Heat Exchange
Qty 1
Freezing Fluid Flow (m3/h)
Based on Cryogenic Tem. -8ºC
9 12 13 16
Freezing Fluid Flow (m3/h)
Based on Cryogenic Tem. -10ºC
9 11 12 15
Freezing Water Flow (m3/h) 23 28 33 38
Head Loss (m3/h) 54 54 57 59
Pipe Dia. (m3/h) 2-1/2" 2-1/2" 2-1/2" 2-1/2"
Condenser Type Shell and Tube Type High Efficiency Heat Exchange
Qty 1
Cooling Water Flow (m3/h)
Based on Cryogenic Tem. -8ºC
16 20 22 26
Freezing Water Flow (m3/h)
Based on Cryogenic Tem. -10ºC
15 19 21 25
Freezing Water Flow (m3/h) 28 35 41 47
Head Loss (m3/h) 51 51 54 54
Pipe Dia. (m3/h) 2" 2" 2" 2"
Protection Devices built in high pressure protector, low pressure protector, overload protector, over-voltage or under-voltage, anti-phase and phase sequence protector, frost-preventive switch
Size L(mm) 2175 2195 2245 2860
W(mm) 935 935 935 1015
H(mm) 1430 1500 1655 1710
Unit Weight Kg 1020 1060 1270 1370
Operation Weight Kg 1120 1180 1420 1550
Operation Noise Db (A) 72 72 76 76

Work Condition :

1. The above data is based on brine inlet temp -3ºC, outlet temp -8ºC, cooling water inlet temp 30ºC, outlet temp 35ºC,
    fouling factor 0.0001ºC/W.

2. No prior notice if any modified about above specification.

3. Please always confirm before you order.



Structure Drawing

Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors

Work Principle
Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors

Applications

Be widely used in plastics, electroplating, electronics manufacturing, pharmaceutical chemicals, food processing, refrigeration and
other industrial establishments and guesthouses, hotels, shopping malls, office buildings and other types of civil air-conditioning
system.


Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors
Package & Shipping


(1) Use standard export plywood case with forklift truck feet, easy to load and unload .

(2) 5-7 days to finish the production after receiving the deposit .

(3) Shipping by LCL or FCL .


Low Temperature Easy Maintenance Glycol Water Cooling Chiller with Screw Compressors

After-sales service

(1) 12 months quality warranty since the date of delivery.

(2) Free of charge to replace new chillersif quality problems.

(3) Cost price to buy extra parts with Chillers from Ruihai if needed.

(4) 24 hours online service by e-mail, WhatsApp, Skype or Telephone Calling.

(5) Installation Video to help installation even send engineer to customer's jobsite if needed.



Necessary info to Quote

1.What is your cooling capacity?_____    Kcal/hr  or   _____KW ?

2. What's your power supply?  For example: 220V-50Hz-1N (N=Phase )

3.What refrigerant type do you require? R134a or R407c ?

4. What's your ambient temperature? And what is your chiller inlet and outlet water temperature ?

5. Which industry do you use the chiller in ?


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier